116 research outputs found

    Proposal for PS beam tests of a fast rich detector

    Get PDF
    A full scale prototype Fast RICH detector with pad readout for unambiguous imaging has been constructed for operation in a high luminosity environment. It uses the best photosensitive gas capable of fast response (TEA) or the intrinsically fast solid photocathode (CsI/TMAE), developed specifically for this purpose. It can be used at e+e- or hadron colliders as well as at fixed target facilities. It has time resolution of 20 ns with a 1.3 microsecond pipeline and parallel readout of 4000 pad sectors. Fast digital VLSI electronics has been developed for readout and 24000 channels have been tested. The prototype device (12000 pad channels) is assembled and ready for beam tests in 1993

    SELEX RICH Performance and Physics Results

    Get PDF
    SELEX took data in the 1996/7 Fixed Target Run at Fermilab. The excellent performance parameters of the SELEX RICH Detector had direct influence on the quality of the obtained physics results.Comment: Contributed talk at the Fourth Workshop on RICH Detectors, June 5-10, 2002, Pylos, Greece. Accepted for publication in NIM

    Performance of a C4F8O Gas Radiator Ring Imaging Cherenkov Detector Using Multi-anode Photomultiplier Tubes

    Full text link
    We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes. This system was developed to identify charged particles in the momentum range from 3-70 GeV/c for the BTeV experiment.Comment: 28 pages, 23 figures, submitted to Nuclear Instruments and Method

    The X-HPD -Conceptual Study of a Large Spherical Hybrid Photodetector

    Get PDF
    Abstract We present the results of a conceptual study demonstrating the feasibility of a large spherical hybrid photodetector with central anode. A prototype tube with 208 mm diameter and an anode in form of a metallic cube has been fabricated. In the final version of the so-called X-HPD concept the anode will be a scintillator cube with plated faces and a small photodetector to read out the bottom. The bialkali photocathode covers three quarters of the sphere surface. Combined use of this cathode in transmissive and reflective mode leads to effective quantum efficiency values exceeding those obtained in conventional hemispherical PMT designs. Further features of the concept are a photoelectron collection efficiency approaching 100% and a photon amplification in the scintillator crystal leading to a distinct single photoelectron signal. Using a custom built electron accelerator based on a CsI transmissive photocathode, LSO and YAP block crystals in geometries adapted to the anode of an X-HPD have been tested with single photoelectrons in the 10-30 keV energy range. The scintillation light was read out with a conventional PMT or a Si-PM. More than 30 photoelectrons per incident electron could be detected with the PMT

    The CLEO-III Ring Imaging Cherenkov Detector

    Get PDF
    The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.Comment: Invited talk by R.J. Mountain at ``The 3rd International Workshop on Ring Imaging Cherenkov Detectors," a research workshop of the Israel Science Foundation, Ein-Gedi, Dead-Sea, Israel, Nov. 15-20, 1998, 14 pages, 9 figure

    The Cleo Rich Detector

    Full text link
    We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel ``sawtooth''-shaped exit surface. Photons in the wavelength interval 135--165 nm are detected using multi-wire chambers filled with a mixture of methane gas and triethylamine vapor. Excellent pion/kaon separation is demonstrated.Comment: 75 pages, 57 figures, (updated July 26, 2005 to reflect reviewers comments), to be published in NIM

    Novel geometrical concept of a high-performance brain PET scanner. Principle, design and performance estimates

    Get PDF
    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high-resolution positron emission tomograph. The concept, which can be for example implemented in a brain PET device, promises to lead to an essentially parallax-free 3D image reconstruction with excellent spatial resolution and constrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state-of-the art brain PET device. We finally describe a dedicated data acquisition system, capable to fully exploit the advantages of the proposed concept. We conclude that the proposed 3D axial concept and the discussed implementation is a competitive approach for high-resolution brain PET. Excellent energy resolution and Compton enhanced sensitivity are expected to lead to high-quality reconstruction and reduced scanning times

    Experimental study of a proximity focusing Cherenkov counter prototype for the AMS experiment

    Get PDF
    A study prototype of Proximity Focussing Ring Imaging Cherenkov counter has been built and tested with several radiators using separately cosmic-ray particles and 12C beam fragmentation products at several energies. Counter prototype and experimental setup are described, and the results of measurements reported and compared with simulation results.The performances are discussed in the perspective of the final counter design.Comment: 27 pages, 16 figures, submitted to NIM

    Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research*

    Get PDF
    A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr3:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial field-of-view of approximately 15 cm dedicated to brain research. The design philosophy and performance predictions based on analytical calculations and Monte Carlo simulations are presented. Image correction and reconstruction tools required to operate this transmissionless device in a research environment are also discussed. Better or similar performance parameters were obtained compared to other known designs at lower fabrication cost. The axial geometrical concept also seems to be promising for applications such as positron emission mammography

    Spatial memory in the grey mouse lemur (Microcebus murinus)

    Get PDF
    Wild animals face the challenge of locating feeding sites distributed across broad spatial and temporal scales. Spatial memory allows animals to find a goal, such as a productive feeding patch, even when there are no goal-specific sensory cues available. Because there is little experimental information on learning and memory capabilities in free-ranging primates, the aim of this study was to test whether grey mouse lemurs (Microcebus murinus), as short-term dietary specialists, rely on spatial memory in relocating productive feeding sites. In addition, we asked what kind of spatial representation might underlie their orientation in their natural environment. Using an experimental approach, we set eight radio-collared grey mouse lemurs a memory task by confronting them with two different spatial patterns of baited and non-baited artificial feeding stations under exclusion of sensory cues. Positional data were recorded by focal animal observations within a grid system of small foot trails. A change in the baiting pattern revealed that grey mouse lemurs primarily used spatial cues to relocate baited feeding stations and that they were able to rapidly learn a new spatial arrangement. Spatially concentrated, non-random movements revealed preliminary evidence for a route-based restriction in mouse lemur space; during a subsequent release experiment, however, we found high travel efficiency in directed movements. We therefore propose that mouse lemur spatial memory is based on some kind of mental representation that is more detailed than a route-based network map
    corecore